| Possible Causes | Inspection | Remedy |
|---|---|---|
| Blown fuse | Inspect the fuse and wiring | Replace fuse and repair wiring |
| Broken wiring or bad connection. | Check the fan motor ground and connectors. | Replace |
| Fan motor malfunction | Check the lead wires from the motor with circuit tester. | Replace |
| Broken resistor wiring | Check resistor using a circuit tester. | Replace |
| Fan motor switch malfunction. | Operate the fan switches in sequence and check whether the fan operates. | Replace |
| Possible Causes | Inspection | Remedy |
|---|---|---|
| Evaporator inlet obstruction | Check evaporator inlet and filters. | Remove any obstruction and blow out filters or replace. |
| Air Leak | Check the cooling unit case joints for leaks. | Repair or replace any leakage areas. |
| Defective thermoswitch or cold control switch. (frozen evaporator) | Check the switch using a circuit tester. | Replace. |
Request Information |
ISO 9001:2008 | News |
|---|---|---|
| Perrin Manufacturing is committed to providing you with superior products and services; we renew this pledge through continual improvement of our products and motivation of our staff. We faithfully comply with all of the requirements of our ISO 9001:2008 Quality Management System, the most current edition of the standard. Beyond that, our highly trained quality staff persistently search for new ways to improve the effectiveness of our system. |
|